Abnormal waveform Medical simulator , ECG signal simulator PLG-2000SUP

Abnormal waveform Medical simulator , ECG signal simulator PLG-2000SUP
Abnormal waveform Medical simulator , ECG signal simulator PLG-2000SUP Abnormal waveform Medical simulator , ECG signal simulator PLG-2000SUP

Large Image :  Abnormal waveform Medical simulator , ECG signal simulator PLG-2000SUP

Product Details:
Place of Origin: CN
Brand Name: Precise Life
Model Number: PLG-2000SUP
Payment & Shipping Terms:
Minimum Order Quantity: 1 unit
Price: Negotiate
Packaging Details: 1 unit per case
Delivery Time: Within 7 days
Payment Terms: T/T, Western Union,Paypal
Supply Ability: 1000 pcs per week
Detailed Product Description
Name: ECG Signal Simulator Application: Medical Signal Simulate
Material: Plastic Color: Yellow
Battery Type: Build-in Lithium
High Light:

Hospital Simulator

,

Medicine Simulator

PLG-2000SUP Abnormal waveform ECG signal simulator PVC,VPC, ECG signal generator, Arrhythmia ECG simulator
 
 
Introduction:
 
This model simulator suitable for ECG machine manufacturer, or ECG kind product manufacturer. It can be used to adjust machine, and use for ECG machine development.
 
Feature:
 
Rechargeable Lithium battery
10 pcs multi-functional ECG connector, can be connect with different type ECG machine cable or patient monitor cable
Battery power indicate light
Low battery power automatic turn off function, protect the Lithium battery
 
Description
 
The waveform type description ( using the Mindray PM8000 monitor detection )
1, waveform code 1: normal ECG waveform
The data code at 60 is mean :heart rate 60 bpm
The frequency range is 10-200 BPM and wave amplitude is fixed, it will not be affected by the amplitude setting.
2, waveform code 2: It is represent triangular waveform waveform code
Data code at 75 : it is mean heart rate 75bpm
Frequency range: 10-400bpm
Amplitude range: 0.1-4mV, the amplitude can be regulated in regulate setting place
3, waveform code 3: Square waveform
Data code at 10 : it is mean 1Hz
Frequency range: 0.1-10Hz
Amplitude range: 0.1-4mV, the amplitude can be regulated in regulate setting place
4, Waveform code 4 :Sinusoidal waveform
Data code at 10 : it is mean 10Hz
Frequency range : 1-100Hz
Amplitude range: 0.1-4mV, the amplitude can be regulated in regulate setting place
5, Waveform code 5: QRS wave waveform
You can change the amplitude of T wave, QRS wave amplitude, width of QRS wave, QRS wave frequency
To change these parameters through the combination of keys
6.Waveform code at 6: Respiratory waveform
Data code at 30: it is mean 30bpm
Respiratory waveform frequency adjustment range 10-120 times
7, Waveform code 7: pacing signal ,the pacing pulse signal of positive and negative direction
Data code at 20 ( It is represent 2mS )
The frequency is 60bpm
Amplitude range: 0.1-4mV, the amplitude can be regulated in regulate setting place
Through the combination of keys to switch the positive and negative direction
You can change the pulse width, the range is 0.5-2mS
8, Waveform code 8: QRS wave of front pacing signals
Front pacing signal is positive and negative pulse waveform, through the combination of keys to switch
The width of pacing signal pulse can be adjusted, the range is 0.5-2mS
Amplitude range: 0.1-4mV, the amplitude can be regulated in regulate setting place
9, Waveform code 9: adjust the waveform amplitude
Data code at100 : it is represent 1Mv
400: it is represent 4Mv
10, waveform code at A:
 

Data code
 

bpm Symptom

Data code at 1
 

75bpm Normal

Data code at 2
 

140bpm Tachycardia

Data code at 3
 

35bpm Bradycardia
Data code at 4 200bpm T supraventricular tachycardia

Data code at 5
 

80(73)bpm Missed beat

Data code at 6
 

14 bpm Agony rhythm

Data code at 7
 

0 bpm Cardioplegia

 
11, Waveform code at B:
 

Data code
 

bpm Symptom

Data code 1
 

75 bpm Normal

Data code 2
 

82 bpm NSR with PAC
Data code at 3 82 bpm Coarse atrial fibrillation, arhythmia
Data code at 4 80 bpm premature ventricular contraction
Data code at 5 80 bpm Continuation 2 premature ventricular contraction
Data code at 6 80 bpm Continuation 3 premature ventricular contraction
Data code at 7 80 bpm Continuation 4 premature ventricular contraction

Data code 8
 

80 bpm Premature beat
Data code 9 80 bpm 2 continuation premature beat
Data code 10 80 bpm 4 continuation premature beat
Data code 11 80 bpm 1 premature beat,1 normal waveform

Data code 12
 

80 bpm All premature beat(VF/VT)

 
12, waveform code at C:
 

Data code
 

bpm Symptom

Data code at 1
 

60 bpm Degree block

Data code at 2
 

35 bpm Degree block 30 bpm

Data code at 3
 

31 bpm Degree block 31 bpm

Data code at 4
 

60 bpm L bnd1 branch block

Data code at 5
 

60 bpm R bnd1 branch block

 
13, waveform code at D:
 

Data code number
 

bpm Symptom

Data code at 1
 

(80-83) bpm ATRIAL PAC

Data code at 2
 

60 bpm Pvc1 early Lv focus

Data code at 3
 

60 bpm Pvc1 early Rv focus

Data code at 4
 

60 bpm Nodal pnc

Data code at 5
 

60 bpm PVCs bigeminy

Data code at 6
 

60 bpm PVCs trigeminy

Data code at 7
 

80 bpm R ON T

 
 
Abnormal waveform Medical simulator , ECG signal simulator PLG-2000SUP 0
 